ONTAP SAN Implementation (SANIMP)

Ce cours remplace :

SAN Implementation (SANIW)
 

A qui s'adresse cette formation

Professionals who implement SAN solutions that use NetApp storage systems

Certifications

Cette formation prépare à la/aux certifications:

Pré-requis

Objectifs

By the end of this course you should be able to:
  • Define and describe SANs that use FC, FCoE, and iSCSI protocols
  • Configure Windows Server 2012 R2, Red Hat® 6.5, and Data ONTAP® systems for iSCSI connectivity
  • Configure Windows Server 2012 R2, Red Hat 6.5, and Data ONTAP systems for FC and FCoE connectivity
  • Use FC and iSCSI protocols to create and access LUNs from Windows Server 2012 and Red Hat 6.5 systems
  • Create and access a LUN from Windows Server 2012 and Red Hat 6.5
  • Size, clone, copy, move, back up, and recover LUNs on Windows Server 2012 R2 and Red Hat 6.5 systems
  • Troubleshoot SAN connectivity and performance issues

Contenu

In this workshop course, you learn how to connect Windows® and Linux® hosts to NetApp® SANs via FC and iSCSI protocols.

Module 1: SAN Concepts
  • NetApp SAN
  • SAN Protocols
  • SAN Terminology
  • Implementing SAN
  • Designing and Planning a SAN Solution
Module 2: IP SAN Architecture
  • IP SAN Architecture
  • iSCSI Protocol
  • Implementing IP SAN on Data ONTAP
  • Scaling IP SAN In clustered Data ONTAP
Module 3: Windows IP Connectivity
  • Windows iSCSI Configuration
  • Windows iSCSI Implementation
Module 4: Windows LUN
  • LUN Access Overview
  • Windows Setup
  • Volume Management
  • SnapDrive for Windows
Module 5: Linux IP Connectivity
  • Linux iSCSI Configuration
Module 6: Linux LUN
  • LUN Access Review
  • Linux Setup
  • Volume Management
Module 7: FC SAN Architecture
  • FC SAN Architecture
  • FC SAN Connections
  • FC Protocol
Module 8: FC SAN Fabrics
  • Fabric Design
  • FC Initialization
  • Switch Concepts
  • FC Zoning
  • Scaling FC SAN in clustered Data ONTAP
Module 9: Windows FC Connectivity
  • Windows FC Connectivity
  • Data ONTAP 7-Mode CF Modes
  • Windows Configuration
  • Discovery and Provisioning
Module 10: Unified Connect
  • Unified Connect
  • FCoE-Enabling Technologies
  • End-to-End FCoE Configuration
  • FC-to-FCoE Connectivity
Module 11: Linux FC
  • Linux FC Configuration
  • SnapDrive for Unix
Module 12: LUN Provisioning
  • LUN Provisioning
  • LUN Overwrite Reservations
  • SAN Provisioning Options
  • HOST-Side Space Management
  • Keeping LUNs Online
Module 13: Host Considerations
  • Common Disk Structures
  • Multipathing
  • Clustered Data ONTAP Path Changes
  • Selective LUN Mapping in Clustered Data ONTAP 8.3
  • Queue Depth
Module 14: SAN Management
  • Port and Logical Interface Management
  • LUN Management
  • LUN Mobility
  • Copy Offload
  • LUN Cloning
  • Protecting a LUN
  • Removing a LUN
Module 15: SAN Troubleshooting
  • SAN Troubleshooting
  • Data ONTAP Troubleshooting
  • NetApp Data Center Tools

Appendix A: Windows Miscellaneous

  • Windows Server 2012 CLI
  • Windows Server 2012 Server Core
  • Dynamic disks

Appendix B: Brocade Configuration

  • Fabric OS
  • Management IP address configuration
  • Setting configuration
  • Zone configuration

Appendix C: Cisco Configuration

  • NX-OS
  • Initial configuration
  • Port configuration
  • Zone configuration

Appendix D: Scalable SAN Failover

  • SAN architecture
  • SAN operations
  • CLAM quorum
  • Epsilon administration

Appendix E: SAN Migration

  • Foreign LUN import

New Features Addendum: ONTAP 9.1

  • ONTAP 9 introduction
  • ONTAP 9.1 highlights
  • 12-node SAN clusters
  • Simply anywhere
  • OTNAP select
  • OnCommand management portfolio
  • SAN management enhancements
  • All Flash FAS
  • SnapCenter 2.0
  • 9.1 hardware refresh
Labs
  • Verify the cluster from the CLI
  • Verify the cluster from OnCommand System Manager
  • Use the NetApp OnCommand System Manager to create a data aggregate
  • Use the NetApp OnCommand System Manager to create a subnet for an SVM
  • Use the NetApp OnCommand System Manager to create an SVM for iSCSI
  • Set up Multipath I/O on Microsoft Windows Server 2012 R2
  • Install the host utilities kit on Microsoft Windows Server 2012 R2
  • Configure iSCSI sessions on Microsoft Windows Server 2012 R2
  • Confirm iSCSI sessions on the data ONTAP operating system
  • Create a local administrative account for NetApp software
  • Install NetApp SnapDrive for Windows on Microsoft Windows Server 2012
  • Create a Window iSCSI disk with SnapDrive for Windows
  • Verify the Linux configuration
  • Install the NetApp Linux host utilities on your Linux system
  • Configure the iSCSI software initiator for Linux
  • Confirm the iSCSI connections
  • Enable the Linux native multipathing
  • Create iSCSI-attached LUNs for Linux
  • Discover iSCSI-attached LUNs for Linux
  • Prepare an individual LUN and mount it on Linux
  • Configure an LVM2 logical volume
  • Review key FC concepts
  • Investigate the initial switch configuration
  • Configure FC HBAs on a storage system
  • Configure an SVM for FC connectivity
  • Install QLogic FC tool on Windows 2012 R2 system
  • Enable FC HBA ports on a Windows 2012 R2 system
  • Assign aliases to WWPNs on a storage system
  • Provide LUN access by using the CLI
  • Create a Windows volume by using FC-attached NetApp LUNs
  • Create a VLAN on the switch
  • Configure a target FCoE port on the switch
  • Configure an initiator FC port on the switch
  • Set up one-to-one zone mapping between the initiator and target port
  • Install SnapDrive for Linux
  • Create a LUN by using SnapDrive for Linux
  • Use SnapDrive for Unix to recover data
  • Create an FC-attached LUN with system manager
  • Create a Snapshot copy of a LUN
  • Observe the effects of writing to a LUN
  • Observe the effects of deleting data from a LUN
  • Observe the effects of overwriting to a LUN
  • Observe the effects of setting a Snapshot automatic deletion policy
  • Review the key host considerations
  • Examine FC HBA port configuration
  • Expand and shrink a LUN
  • Clone a LUN for Windows
  • Copy and move a LUN
  • Remove a LUN from Windows
  • Reset the storage HBAS to initiator mode
  • Download nSANity
  • Examine nSANity commands
  • Collect system data
  • Viewing nSANity files

Prix & Delivery methods

Formation en ligne

Durée
3 jours

Prix
  • CHF 3 510,–
  • NetApp Training Units : 36 NTU
Formation en salle équipée

Durée
3 jours

Prix
  • Suisse : CHF 3 510,–
  • NetApp Training Units : 36 NTU

Agenda

Instructor-led Online Training:   Course conducted online in a virtual classroom.
FLEX Classroom Training (hybrid course):   Course participation either on-site in the classroom or online from the workplace or from home.

Allemand

Fuseau horaire : Heure d'été d'Europe centrale (HAEC)

Formation en ligne
Option présentielle : Hambourg, Allemagne
Fuseau horaire : Heure d'été d'Europe centrale (HAEC)
Formation en ligne Fuseau horaire : Heure d'été d'Europe centrale (HAEC)
Formation en ligne
Option présentielle : Vienne (iTLS), Autriche
Fuseau horaire : Heure d'été d'Europe centrale (HAEC)
Formation en ligne
Option présentielle : Zurich
Fuseau horaire : Heure d'été d'Europe centrale (HAEC)
Formation en ligne
Option présentielle : Zurich
Fuseau horaire : Heure d'été d'Europe centrale (HAEC)
Formation en ligne
Option présentielle : Berlin, Allemagne
Fuseau horaire : Heure normale d'Europe centrale (HNEC)
Formation en ligne
Option présentielle : Zurich
Fuseau horaire : Heure normale d'Europe centrale (HNEC)

Anglais

1 heure de différence

Formation en ligne Fuseau horaire : British Summer Time (BST)
Formation en ligne Fuseau horaire : British Summer Time (BST)
Formation en ligne Fuseau horaire : Greenwich Mean Time (GMT)
FLEX Classroom Training (hybrid course):   Course participation either on-site in the classroom or online from the workplace or from home.

Suisse

Zurich
Zurich
Zurich
Zurich

Allemagne

Hambourg
Berlin

Autriche

Vienne (iTLS)

Si vous ne trouvez pas de date adéquate, n'hésitez pas à vérifier l'agenda de toutes nos formations FLEX internationales